<b>검색 상세보기 : [파티클]</b> - Cyto-Cal™<br>Low Intensity Calibrator Particles
Notice

판매개시!
ThermoFisher Scientific® 

Aquanex Ultrapure Water Purification System

Aquanex


- 사용하기 쉬운 디자인
- 언제든지 신뢰할 수 있는 수질 제공
- 먼 거리에서도 수질, 분주타임, 탱크 수위 확인
- 쉬운 유지보수 및 셀프 서비스 설계
- 향상된 정확도 및 재현성 제공

     
 
Home > Product > 파티클 > Thermo > Flow Cytometry

제 품 명 : Cyto-Cal™
Low Intensity Calibrator Particles
제 조 사 : Thermo
제품코드 : FL6
관련자료: Cyto-Cal-LowIntensity .jpg (11,933 KB)
 
   
상세설명


Cyto-Cal™ Low Intensity Calibrator Particles

In many flow cytometry applications, it is critical to be able to separate dimly labeled cells from unlabeled (autofl uorescent) cells. Cyto-Cal Low Intensity Calibrator enables simultaneous monitoring of FL1 (FITC), FL2 (PE), FL3 (PE-Cy5) and FL4 (APC) channels for adequate fl uorescence sensitivity and discrimination.

The calibrator contains an equal mixture of 6 μm undyed particles and particles dimly abeled with green, orange and red fluorescent dyes which are designed to imitate a mixture of unlabeled and dim labeled cells. The dyes are incorporated within the polymer matrix (hard-dyed) for long term stability using a proprietary Firefli process.
  • Superlor bead size uniformtiy and dye intensity uniformity
  • Routine monitoring of low-end sensitivity
Storage Conditions: Refrigerate when not in use; do not freeze. Store upright and keep bottle tightly sealed. Mix product by gentle inversion by hand or vortex mixer.
Recommended for: Liquid particle counting and sizing calibration. Product can assist in USP <788> and <789> interim verification.

Specifications
Composition Polystyrene microspheres containing encapsulated dyes
Dye Type Firefli Fluorescent Green (488/510nm), Red (488/633/635/700nm), Orange (488/575nm)
Particle Density 1.06 g/cm3
Fill Volume 3 mL
Concentration 4 x 106 particles / mL
Content Dyed polymer microspheres in water
Additive 0.05% Tween-20 Dispersant / Surfactant with 2 mM Sodium Azide preservative
Stability ≥ 12 months
Includes Material Safety Data Sheet (MSDS) and Package Insert Sheet
Storage Requirements Refrigerate when not in use; do not freeze. Store upright and keep bottle tightly sealed. Mix product by gentle inversion by hand or vortex mixer.

Cat. No. Description
FL6 6 µm, 4 x 106 particles/mL, 3 mL(50 tests)


 

Map
Anyang Mega Valley RM 819, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Republic of Korea 14056
【Tel】+82-(0)2-571-3444 【Fax】+82-(0)2-571-4877
【email】 jys@jysco.com

Copyrightⓒ ㈜장영실 JYSCO Co., Ltd. All Rights Reserved.